Smart Camera - pictor N403C-ETH
Characteristics
- smart camera for industrial image processing
- particularly compact and space-saving design
- integrated HMI for process visualization
- consistent functional and operating concept, range of functions is compatible with vicosys® vision systems
- on average 2.5 times faster than comparable pictor® M devices
- extensive optics and lighting accessories
Technical data
| Sensor Data | |
| Sensor name | e2v EV76C541 |
| Chroma | Colour IR cut filter 400 nm - 700 nm |
| Sensor format | 1/4" |
| Sensor diagonal | 4.01 mm |
| Sensor technology | CMOS |
| Readout method | Global Shutter |
| Resolution total | 0.3 MPixel |
| Number of pixel | 752 x 480 Pixel |
| Pixel size | 4.5 µm x 4.5 µm |
| Frame rate | 125 fps |
| Shutter (exposure time) | min. 34 µs |
| Performance Data | |
| Processor | Dual-Core ARM®Cortex®-A9 with 866MHz and integrated FPGA |
| RAM | 512 MB DDR-SDRAM |
| Flash EPROM | 16 GB - of which approx. 12 GB free for test programs and images |
| Prozessinterface | |
| Communication interfaces | 1 x Ethernet 100Mbit |
| Process interface | 2 x digitaler Eingangskanal 4 x digitale Ausgangskanal 1 x Trigger-Eingang für Bildaufnahme 1 x Trigger-Ausgang für Blitz |
| Software | |
| Parameterization | Operating software vcwin |
| Operation | Process visualization and configuration via integrated webHMI |
| General Data | |
| Power requirements | 12 V ... 30 V DC via 12-pin Hirose or power supply |
| Lens mount | CS-Mount, C-Mount (with adapter) |
| Dimensions | 80 mm x 45 mm x 20 mm (without connectors) |
| Weight | 175 g |
| Degree of protection (IP) | IP20 |
| Safety class | Class III, safety extra low voltage (SELV) |
| Operating temperature | 0 °C ... 50 °C |
Accessories for Lighting - pictor N403C-ETH
| Order number | Title | Description |
|---|---|---|
| Ethernet Cables | ||
| 4-40-203 | Ethernet cable, 6p, 5m | HR10A-7P-6S, plug with socket contacts to RJ45 plug, for pictor M/N |
| 4-40-204 | Ethernet cable, 6p, 10m | HR10A-7P-6S, plug with socket contacts to RJ45 plug, for pictor M/N |
| 4-40-206 | Ethernet cable, 6p, 20m | HR10A-7P-6S, plug with socket contacts to RJ45 plug, for pictor M/N |
| PLC-Power Cables | ||
| 4-40-223 | PLC-power cable, 12p, 5m | HR10A-10P-12S, plug with socket contacts to open cable end, for pictor M/N |
| 4-40-224 | PLC-power cable, 12p, 10m | HR10A-10P-12S, plug with socket contacts to open cable end, for pictor M/N |
| 4-40-225 | PLC-power cable, 12p, 25m | HR10A-10P-12S, plug with socket contacts to open cable end, for pictor M/N |
| Power supply units | ||
| 4-40-209 | Power supply 24V/0.63A | HR10A-10P-12S, plug with socket contacts, length 3m, for pictor M/N |
| Fieldbus Gateways | ||
| 3-90-028 | Gateway netTAP 50-DP-EN | Modbus TCP slave to PROFIBUS-DP slave, for pictor and vicosys |
| Power supply | ||
| 4-40-219 | Power supply 24V-40W-1.7A | for DIN rail mounting, without connection cable, type: MDR-40-24 |