Digital lightingcontroller with vicolux® smart light technology

Lighting controllers of Vision & Control provide for stable lighting conditions and a high failure security of LED-lights in the industrial sphere. They are easy to use and to integrate in the operation.

 

The smart light-lighting controller DLC3005 supervises on-line all working conditions of the lighting and guarantees the safe and undisturbed operation free of failure of the connected lighting within their achievement borders with suitable configuration.

Usage

  • In combination with connected vicolux® smart light lightings the DLC3005 monitors operating modes of the lighting and provides support for configuration
  • Suitable as a power source also for high performance LED-lighting of other manufacturers.

 

Productview
Product information
DLC3005
Title:
DLC3005
Short description:
LED lighting controller, digital, cont./flash current: 4.8A/18A, wall mounting
Order number:
1-30-202
Downloads:
Show details
Characteristics
  • for high performance LED-lightings of all kind
  • Sturdy and low-space design
  • Simple assembly and operation
  • Enormous power density
  • Industrial standard connector
  • Two digital in- and outputs, PLC-compatible
  • Adjustable via web-interface or manually
Drawings
DLC3005-R
Title:
DLC3005-R
Short description:
LED lighting controller, digital, cont./flash current: 4.8A/18A, DIN rail mounting
Order number:
1-30-209
Downloads:
Show details
Drawings
  • 1

Facts worth knowing about vicolux® smart light technology

"One-wire" communication between lighting and power source and "smart light parameters" that are stored in the lighting unit enable the lighting controller to adapt automatically to the attached LED lighting.

The controller also continuously records and evaluates the operating status of the lighting and thereby protects it from fast aging and destruction.

vicolux® smart light technology

  • Ensures compliance with the works settings for the limit values of LED lighting in continuous and flash operation
  • Provides parameters for, say, maximum current at an ambient temperature of 25 °C and free convection and supports integration of the lighting into the image processing system
  • Monitors, in addition to flash current, switching-on and interval times (the duty cycle) in flash operation

Each lighting unit incorporates the brightness value setting of the first illumination batch manufactured at Vision & Control. That enables the user to adjust, if required, the brightness of future units that might be brighter to the brightness of the first batch.